38,134 research outputs found
A Note on Tubular Brane Dynamics
We present new time dependent solutions for the dynamics of tubular
D2-branes. We comment on the connection to cosmic string dynamics and
explicitly give a few simple examples of oscillating and rotating brane
configurations.Comment: 1+6 pages, 2 Figure
On the absolute value of the air-fluorescence yield
The absolute value of the air-fluorescence yield is a key parameter for the
energy reconstruction of extensive air showers registered by fluorescence
telescopes. In previous publications, we reported a detailed Monte Carlo
simulation of the air-fluorescence generation that allowed the theoretical
evaluation of this parameter. This simulation has been upgraded in the present
work. As a result, we determined an updated absolute value of the fluorescence
yield of 7.9+-2.0 ph/MeV for the band at 337 nm in dry air at 800 hPa and 293
K, in agreement with experimental values. We have also performed a critical
analysis of available absolute measurements of the fluorescence yield with the
assistance of our simulation. Corrections have been applied to some
measurements to account for a bias in the evaluation of the energy deposition.
Possible effects of other experimental aspects have also been discussed. From
this analysis, we determined an average fluorescence yield of 7.04+-0.24 ph/MeV
at the above conditions.Comment: Submitted to Astroparticle Physic
Comparison of available measurements of the absolute air-fluorescence yield and determination of its global average value
Experimental results of the absolute air-fluorescence yield are given very
often in different units (photons/MeV or photons/m) and for different
wavelength intervals. In this work we present a comparison of available results
normalized to its value in photons/MeV for the 337 nm band at 1013 hPa and 293
K. The conversion of photons/m to photons/MeV requires an accurate
determination of the energy deposited by the electrons in the field of view of
the experimental set-up. We have calculated the energy deposition for each
experiment by means of a detailed Monte Carlo simulation and the results have
been compared with those assumed or calculated by the authors. As a result,
corrections to the reported fluorescence yields are proposed. These corrections
improve the compatibility between measurements in such a way that a reliable
average value with uncertainty at the level of 5% is obtained.Comment: 13 pages, 6 figures. To appear in the Proocedings of the
International Symposium on the Recent Progress of Ultra-high Energy Cosmic
Ray Observations (UHECR2010), Nagoya, Japan, 201
- …