4 research outputs found

    Thermionic Emission and Tunneling at Carbon Nanotube–Organic Semiconductor Interface

    No full text
    We study the charge carrier injection mechanism across the carbon nanotube (CNT)–organic semiconductor interface using a densely aligned carbon nanotube array as electrode and pentacene as organic semiconductor. The current density–voltage (<i>J–V</i>) characteristics measured at different temperatures show a transition from a thermal emission mechanism at high temperature (above 200 K) to a tunneling mechanism at low temperature (below 200 K). A barrier height of ∼0.16 eV is calculated from the thermal emission regime, which is much lower compared to the metal/pentacene devices. At low temperatures, the <i>J–V</i> curves exhibit a direct tunneling mechanism at low bias, corresponding to a trapezoidal barrier, while at high bias the mechanism is well described by Fowler–Nordheim tunneling, which corresponds to a triangular barrier. A transition from direct tunneling to Fowler–Nordheim tunneling further signifies a small injection barrier at the CNT/pentacene interface. Our results presented here are the first direct experimental evidence of low charge carrier injection barrier between CNT electrodes and an organic semiconductor and are a significant step forward in realizing the overall goal of using CNT electrodes in organic electronics

    Semiconducting Enriched Carbon Nanotube Aligned Arrays of Tunable Density and Their Electrical Transport Properties

    No full text
    We demonstrate assembly of solution-processed semiconducting enriched (99%) single-walled carbon nanotubes (s-SWNTs) in an array with varying linear density via ac dielectrophoresis (DEP) and investigate detailed electronic transport properties of the fabricated devices. We show that (i) the quality of the alignment varies with frequency of the applied voltage and that (ii) by varying the frequency and concentration of the solution, we can control the linear density of the s-SWNTs in the array from 1/μm to 25/μm. The DEP assembled s-SWNT devices provide the opportunity to investigate the transport property of the arrays in the direct transport regime. Room temperature electron transport measurements of the fabricated devices show that with increasing nanotube density the device mobility increases while the current on–off ratio decreases dramatically. For the dense array, the device current density was 16 μA/μm, on-conductance was 390 μS, and sheet resistance was 30 kΩ/◻. These values are the best reported so far for any semiconducting nanotube array

    Fabrication of Organic Field Effect Transistor by Directly Grown Poly(3 Hexylthiophene) Crystalline Nanowires on Carbon Nanotube Aligned Array Electrode

    No full text
    We fabricated organic field effect transistors (OFETs) by directly growing poly (3-hexylthiophne) (P3HT) crystalline nanowires on solution processed aligned array single walled carbon nanotubes (SWNT) interdigitated electrodes by exploiting strong π−π interaction for both efficient charge injection and transport. We also compared the device properties of OFETs using SWNT electrodes with control OFETs of P3HT nanowires deposited on gold electrodes. Electron transport measurements on 28 devices showed that, compared to the OFETs with gold electrodes, the OFETs with SWNT electrodes have better mobility and better current on−off ratio with a maximum of 0.13 cm2/(V s) and 3.1 × 105, respectively. The improved device characteristics with SWNT electrodes were also demonstrated by the improved charge injection and the absence of short channel effect, which was dominant in gold electrode OFETs. The enhancement of the device performance can be attributed to the improved interfacial contact between SWNT electrodes and the crystalline P3HT nanowires as well as the improved morphology of P3HT due to one-dimensional crystalline nanowire structure

    Label-Free Neuropeptide Detection beyond the Debye Length Limit

    No full text
    Biosensors with high selectivity, high sensitivity, and real-time detection capabilities are of significant interest for diagnostic applications as well as human health and performance monitoring. Graphene field-effect transistor (GFET) based biosensors are suitable for integration into wearable sensor technology and can potentially demonstrate the sensitivity and selectivity necessary for real-time detection and monitoring of biomarkers. Previously reported DC-mode GFET biosensors showed a high sensitivity for sensing biomarkers in solutions with a low salt concentration. However, due to Debye length screening, the sensitivity of the DC-mode GFET biosensors decreases significantly during operation in a physiological fluid such as sweat or interstitial fluid. To overcome the Debye screening length limitation, we report here alternating current (AC) mode heterodyne-based GFET biosensors for sensing neuropeptide-Y (NPY), a key stress biomarker, in artificial sweat at physiologically relevant ionic concentrations. Our AC-mode GFET biosensors show a record ultralow detection limit of 2 × 10–18 M with an extensive dynamic range of 10 orders of magnitude in sensor response to target NPY concentration. The sensors were characterized for various carrier frequencies (ranging from 30 kHz to 2 MHz) of the applied AC voltages and various salt concentrations (10, 50, and 100 mM). Contrary to DC-mode sensing, the AC-mode sensor response increases with an increase in salt concentration in the electrolyte. The sensor response can be further enhanced by tuning the carrier frequency of the applied AC voltage. The optimum response frequency of our sensor is approximately 400–600 kHz for salt concentrations of 50 and 100 mM, respectively. The salt-concentration- and frequency-dependent sensor response can be explained by an electrolyte-gated capacitance model
    corecore