2,541 research outputs found

    The CMS Muon System

    Get PDF

    Web-based monitoring tools for Resistive Plate Chambers in the CMS experiment at CERN

    Get PDF
    The Resistive Plate Chambers (RPC) are used in the CMS experiment at the trigger level and also in the standard offline muon reconstruction. In order to guarantee the quality of the data collected and to monitor online the detector performance, a set of tools has been developed in CMS which is heavily used in the RPC system. The Web-based monitoring (WBM) is a set of java servlets that allows users to check the performance of the hardware during data taking, providing distributions and history plots of all the parameters. The functionalities of the RPC WBM monitoring tools are presented along with studies of the detector performance as a function of growing luminosity and environmental conditions that are tracked over time

    Design and optimization of a hadronic calorimeter based on micropattern gaseous detectors for a future experiment at the Muon Collider

    Full text link
    Micro-pattern gaseous detectors (MPGDs) are a promising readout technology for hadronic calorimeters (HCAL) thanks to their good space resolution, longevity and rate capability. We describe the development of a HCAL based on MPGDs for an experiment at the proposed Muon Collider. The design of a semi-digital MPGD-HCAL is shown and its performance is calculated with Monte Carlo simulations with high-energy pions, showing an energy resolution down to 8\% for \SI{80}{\giga\eV} pions. We also present the performance of twelve MPGD prototypes with different technologies (MicroMegas, ÎŒ\mu-RWELL and RPWELL) assembled and operated in test beam first with high-energy muons and later with pions in a hadronic calorimeter prototype of ∌1 λI\sim1\,\lambda_\text{I} length; the detectors have a good response uniformity (lower than 17\%) and space resolution and their performance in the calorimeter shows very good agreement with the Monte Carlo shower calculation

    Radiation background with the CMS RPCs at the LHC

    Get PDF
    The Resistive Plate Chambers (RPCs) are employed in the CMS Experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This article presents results of the radiation background measurements performed with the 2011 and 2012 proton-proton collision data collected by CMS. Emphasis is given to the measurements of the background distribution inside the RPCs. The expected background rates during the future running of the LHC are estimated both from extrapolated measurements and from simulation

    Development and performance of Triple-GEM detectors for the upgrade of the muon system of the CMS experiment

    Get PDF
    The CMS Collaboration is evaluating GEM detectors for the upgrade of the muon system. This contribution will focus on the R&D performed on chambers design features and will discuss the performance of the upgraded detector

    Quality control and beam test of GEM detectors for future upgrades of the CMS muon high rate region at the LHC

    Get PDF
    Gas Electron Multipliers (GEM) are a proven position sensitive gas detector technology which nowadays is becoming more widely used in High Energy Physics. GEMs offer an excellent spatial resolution and a high particle rate capability, with a close to 100% detection efficiency. In view of the high luminosity phase of the CERN Large Hadron Collider, these aforementioned features make GEMs suitable candidates for the future upgrades of the Compact Muon Solenoid (CMS) detector. In particular, the CMS GEM Collaboration proposes to cover the high-eta region of the muon system with large-area triple-GEM detectors, which have the ability to provide robust and redundant tracking and triggering functions. In this contribution, after a general introduction and overview of the project, the construction of full-size trapezoidal triple-GEM prototypes will be described in more detail. The procedures for the quality control of the GEM foils, including gain uniformity measurements with an x-ray source will be presented. In the past few years, several CMS triple-GEM prototype detectors were operated with test beams at the CERN SPS. The results of these test beam campaigns will be summarised

    Recent results and developments on double-gap RPCs for CMS

    Get PDF
    Abstract A 3 mm wide-gap Resistive Plate Chamber, as proposed for CMS, has been tested in the H2 Cern beam line. Results on efficiency, rate capability, time resolution and cluster size are reported

    Resistive Plate Chambers in avalanche mode: a comparison between model predictions and experimental results

    Get PDF
    Abstract In this paper a model simulating the main aspects of avalanche growth and signal development in Resistive Plate Chambers (RPCs) is presented. The model has been used to compute the performances, in particular, charge distribution and efficiency of single- double- and multi-gap RPCs, and to compare them with the available experimental results. This model could be used to optimize the characteristics of this type of detector with a view to its use in the future large experiments at LHC: ATLAS and CMS

    Search for CP Violation in the Decay Z -> b (b bar) g

    Full text link
    About three million hadronic decays of the Z collected by ALEPH in the years 1991-1994 are used to search for anomalous CP violation beyond the Standard Model in the decay Z -> b \bar{b} g. The study is performed by analyzing angular correlations between the two quarks and the gluon in three-jet events and by measuring the differential two-jet rate. No signal of CP violation is found. For the combinations of anomalous CP violating couplings, h^b=h^AbgVb−h^VbgAb{\hat{h}}_b = {\hat{h}}_{Ab}g_{Vb}-{\hat{h}}_{Vb}g_{Ab} and hb∗=h^Vb2+h^Ab2h^{\ast}_b = \sqrt{\hat{h}_{Vb}^{2}+\hat{h}_{Ab}^{2}}, limits of \hat{h}_b < 0.59and and h^{\ast}_{b} < 3.02$ are given at 95\% CL.Comment: 8 pages, 1 postscript figure, uses here.sty, epsfig.st
    • 

    corecore