2,986 research outputs found

    On-sky observations with an achromatic hybrid phase knife coronagraph in the visible

    Get PDF
    CONTEXT: The four-quadrant phase mask stellar coronagraph, introduced by D. Rouan et al., is capable of achieving very high dynamical range imaging and was studied in the context of the direct detection of extra-solar planets. Achromatic four-quadrant phase mask is currently being developed for broadband IR applications. AIMS: We report on laboratory and on-sky tests of a prototype coronagraph in the visible. This prototype, the achromatic hybrid phase knife coronagraph, was derived from the four-quadrant phase mask principle. METHODS: The instrumental setup implementing the coronagraph itself was designed to record the pre- and post-coronagraphic images simultaneously so that an efficient real-time image selection procedure can be performed. We describe the coronagraph and the associated tools that enable robust and repeatable observations. We present an algorithm of image selection that has been tested against the real on-sky data of the binary star HD80081 (* 38 Lyn). RESULTS Although the observing conditions were poor, the efficiency of the proposed method is proven. From this experiment, we derive procedures that can apply to future focal instruments associating adaptive optics and coronagraphy, targeting high dynamic range imaging in astronomy, such as detecting extra-solar planets

    Optimization of Apodized Pupil Lyot Coronagraph for ELTs

    Full text link
    We study the optimization of the Apodized Pupil Lyot Coronagraph (APLC) in the context of exoplanet imaging with ground-based telescopes. The APLC combines an apodization in the pupil plane with a small Lyot mask in the focal plane of the instrument. It has been intensively studied in the literature from a theoretical point of view, and prototypes are currently being manufactured for several projects. This analysis is focused on the case of Extremely Large Telescopes, but is also relevant for other telescope designs. We define a criterion to optimize the APLC with respect to telescope characteristics like central obscuration, pupil shape, low order segment aberrations and reflectivity as function of the APLC apodizer function and mask diameter. Specifically, the method was applied to two possible designs of the future European-Extremely Large Telescope (E-ELT). Optimum configurations of the APLC were derived for different telescope characteristics. We show that the optimum configuration is a stronger function of central obscuration size than of other telescope parameters. We also show that APLC performance is quite insensitive to the central obscuration ratio when the APLC is operated in its optimum configuration, and demonstrate that APLC optimization based on throughput alone is not appropriate.Comment: 9 pages, 17 figures, accepted for publication in Astronomy & Astrophysic

    Speckle Statistics in Adaptively Corrected Images

    Full text link
    (abridged) Imaging observations are generally affected by a fluctuating background of speckles, a particular problem when detecting faint stellar companions at small angular separations. Knowing the distribution of the speckle intensities at a given location in the image plane is important for understanding the noise limits of companion detection. The speckle noise limit in a long-exposure image is characterized by the intensity variance and the speckle lifetime. In this paper we address the former quantity through the distribution function of speckle intensity. Previous theoretical work has predicted a form for this distribution function at a single location in the image plane. We developed a fast readout mode to take short exposures of stellar images corrected by adaptive optics at the ground-based UCO/Lick Observatory, with integration times of 5 ms and a time between successive frames of 14.5 ms (λ=2.2\lambda=2.2 μ\mum). These observations temporally oversample and spatially Nyquist sample the observed speckle patterns. We show, for various locations in the image plane, the observed distribution of speckle intensities is consistent with the predicted form. Additionally, we demonstrate a method by which IcI_c and IsI_s can be mapped over the image plane. As the quantity IcI_c is proportional to the PSF of the telescope free of random atmospheric aberrations, this method can be used for PSF calibration and reconstruction.Comment: 7 pages, 4 figures, ApJ accepte

    Adaptive optics imaging of P Cygni in Halpha

    Full text link
    We obtained Halpha diffraction limited data of the LBV star P Cyg using the ONERA Adaptive Optics (AO) facility BOA at the OHP 1.52m telescope on October 1997. Taking P Cyg and the reference star 59 Cyg AO long exposures we find that P Cyg clearly exhibits a large and diffuse intensity distribution compared to the 59 Cyg's point-like source. A deconvolution of P Cyg using 59 Cyg as the Point Spread Function was performed by means of the Richardson-Lucy algorithm. P Cyg clearly appears as an unresolved star surrounded by a clumped envelope. The reconstructed image of P Cyg is compared to similar spatial resolution maps obtained from radio aperture synthesis imaging. We put independent constraints on the physics of P Cyg which agree well with radio results. We discuss future possibilities to constrain the wind structure of P Cyg by using multi-resolution imaging, coronagraphy and long baseline interferometry to trace back its evolutionary status.Comment: 10 pages, 19 Encapsulated Postscript figure

    Excisional treatment in women with cervical adenocarcinoma in situ (AIS): a prospective randomised controlled noninferiority trial to compare AIS persistence/recurrence after loop electrosurgical excision procedure with cold knife cone biopsy: protocol for a pilot study

    Get PDF
    Introduction: Adenocarcinoma in situ (AIS) of the uterine cervix is the precursor to invasive endocervical adenocarcinoma. An excisional biopsy such as a cold knife cone biopsy (CKC) should be performed to exclude invasive adenocarcinoma. Loop electrosurgical excision procedure (LEEP) is an alternative modality to CKC but is controversial in AIS. There is a perception that there is a greater likelihood of incomplete excision of AIS with LEEP because the depth of excised tissue tends to be smaller and the tissue margins may show thermal artefact which can interfere with pathology assessment. In the USA, guidelines recommend that any treatment modality can be used to excise AIS, provided that the specimen remains intact with interpretable margins. However, there are no high-quality studies comparing LEEP with CKC and well-designed prospective studies are needed. If such a study were to show that LEEP was non-inferior to CKC for the outcomes of post-treatment persistence, recurrence and adenocarcinoma, LEEP could be recommended as an appropriate treatment option for AIS in selected patients. This would benefit women because, unlike CKC, LEEP does not require general anaesthesia and may be associated with reduced morbidity. Methods and analysis: The proposed exploratory study is a parallel group trial with an allocation ratio of 2:1 in favour of the intervention (LEEP: CKC). Participants are women aged ≥18 to ≤45 years diagnosed with AIS on cervical screening and/or colposcopically directed biopsy in Australia and New Zealand, who are to receive excisional treatment in a tertiary level centre. Ethics and dissemination: Ethical approval for the study has been granted by the St John of God Healthcare Human Research Ethics Committee (reference number #1137)

    Speckle noise and dynamic range in coronagraphic images

    Full text link
    This paper is concerned with the theoretical properties of high contrast coronagraphic images in the context of exoplanet searches. We derive and analyze the statistical properties of the residual starlight in coronagraphic images, and describe the effect of a coronagraph on the speckle and photon noise. Current observations with coronagraphic instruments have shown that the main limitations to high contrast imaging are due to residual quasi-static speckles. We tackle this problem in this paper, and propose a generalization of our statistical model to include the description of static, quasi-static and fast residual atmospheric speckles. The results provide insight into the effects on the dynamic range of wavefront control, coronagraphy, active speckle reduction, and differential speckle calibration. The study is focused on ground-based imaging with extreme adaptive optics, but the approach is general enough to be applicable to space, with different parameters.Comment: 31 pages, 18 figure

    Comparison of coronagraphs for high contrast imaging in the context of Extremely Large Telescopes

    Full text link
    We compare coronagraph concepts and investigate their behavior and suitability for planet finder projects with Extremely Large Telescopes (ELTs, 30-42 meters class telescopes). For this task, we analyze the impact of major error sources that occur in a coronagraphic telescope (central obscuration, secondary support, low-order segment aberrations, segment reflectivity variations, pointing errors) for phase, amplitude and interferometric type coronagraphs. This analysis is performed at two different levels of the detection process: under residual phase left uncorrected by an eXtreme Adaptive Optics system (XAO) for a large range of Strehl ratio and after a general and simple model of speckle calibration, assuming common phase aberrations between the XAO and the coronagraph (static phase aberrations of the instrument) and non-common phase aberrations downstream of the coronagraph (differential aberrations provided by the calibration unit). We derive critical parameters that each concept will have to cope with by order of importance. We evidence three coronagraph categories as function of the accessible angular separation and proposed optimal one in each case. Most of the time amplitude concepts appear more favorable and specifically, the Apodized Pupil Lyot Coronagraph gathers the adequate characteristics to be a baseline design for ELTs.Comment: 12 pages, 6 figures, Accepted for publication in A&

    PROGETTO PER UN ECOMUSEO MULTIMEDIALE NELLA BORGATA PARALOUP

    Get PDF
    Descrizione del progetto di "ecomuseo multimediale per la Borgata Paraloup" un museo, essenzialmente multimediale, che sarà diffuso sul erritorio circostante, sotto forma di stimoli sensoriali e di segnalazioni, ma saprà anche porsi in connessione con luoghi più distanti e significativi, nell’idea di costituire Paraloup quale ganglio di una rete di memoria più ampia e sald

    The Lyot Project Direct Imaging Survey of Substellar Companions: Statistical Analysis and Information from Nondetections

    Get PDF
    The Lyot project used an optimized Lyot coronagraph with Extreme Adaptive Optics at the 3.63m Advanced Electro-Optical System telescope (AEOS) to observe 86 stars from 2004 to 2007. In this paper we give an overview of the survey results and a statistical analysis of the observed nondetections around 58 of our targets to place constraints on the population of substellar companions to nearby stars. The observations did not detect any companion in the substellar regime. Since null results can be as important as detections, we analyzed each observation to determine the characteristics of the companions that can be ruled out. For this purpose we use a Monte Carlo approach to produce artificial companions, and determine their detectability by comparison with the sensitivity curve for each star. All the non-detection results are combined using a Bayesian approach and we provide upper limits on the population of giant exoplanets and brown dwarfs for this sample of stars. Our nondetections confirm the rarity of brown dwarfs around solar-like stars and we constrain the frequency of massive substellar companions (M>40Mjup) at orbital separation between and 10 and 50 AU to be <20%.Comment: 32 pages, 11 figures, 2 tables. Published in the Astrophysical Journa
    corecore