An analysis of the impact of datacenter temperature on energy efficiency
Thesis (S.M. in Engineering and Management)--Massachusetts Institute of Technology, Engineering Systems Division, System Design and Management Program; in conjunction with the SDM Fellows Program, 2012.Cataloged from PDF version of thesis.Includes bibliographical references (p. 65-66).The optimal air temperature for datacenters is one of ways to improve energy efficiency of datacenter cooling systems. Many datacenter owners have been interested in raising the room temperature as a quick and simple method to increase energy efficiency. The purpose of this paper is both to provide recommendations on maximizing the energy efficiency of datacenters by optimizing datacenter temperature setpoint, and to understand the drivers of datacenter costs. This optimization and the potential energy savings used in cooling system can drive higher energy use in IT equipment and may not be a good trade off. For this reason, this paper provided a detailed look at the overall effect on energy of temperature changes in order to figure out the optimal datacenter temperature setpoint. Since this optimal temperature range varies by equipment and other factors in the datacenter, each datacenter should identify its appropriate temperature based on the optimization calculation in this paper. Sensitivity analysis is used to identify the drivers of the cost of ownership in a datacenter and to identify opportunities for datacenter efficiency improvement. The model is also used to evaluate potential datacenter efficiency.by Heechang Lee.S.M.in Engineering and Managemen
Holistic Virtual Machine Scheduling in Cloud Datacenters towards Minimizing Total Energy
Energy consumed by Cloud datacenters has dramatically increased, driven by rapid uptake of applications and services globally provisioned through virtualization. By applying energy-aware virtual machine scheduling, Cloud providers are able to achieve enhanced energy efficiency and reduced operation cost. Energy consumption of datacenters consists of computing energy and cooling energy. However, due to the complexity of energy and thermal modeling of realistic Cloud datacenter operation, traditional approaches are unable to provide a comprehensive in-depth solution for virtual machine scheduling which encompasses both computing and cooling energy. This paper addresses this challenge by presenting an elaborate thermal model that analyzes the temperature distribution of airflow and server CPU. We propose GRANITE – a holistic virtual machine scheduling algorithm capable of minimizing total datacenter energy consumption. The algorithm is evaluated against other existing workload scheduling algorithms MaxUtil, TASA, IQR and Random using real Cloud workload characteristics extracted from Google datacenter tracelog. Results demonstrate that GRANITE consumes 4.3% - 43.6% less total energy in comparison to the state-of-the-art, and reduces the probability of critical temperature violation by 99.2% with 0.17% SLA violation rate as the performance penalty
TimeTrader: Exploiting Latency Tail to Save Datacenter Energy for On-line Data-Intensive Applications
Datacenters running on-line, data-intensive applications (OLDIs) consume
significant amounts of energy. However, reducing their energy is challenging
due to their tight response time requirements. A key aspect of OLDIs is that
each user query goes to all or many of the nodes in the cluster, so that the
overall time budget is dictated by the tail of the replies' latency
distribution; replies see latency variations both in the network and compute.
Previous work proposes to achieve load-proportional energy by slowing down the
computation at lower datacenter loads based directly on response times (i.e.,
at lower loads, the proposal exploits the average slack in the time budget
provisioned for the peak load). In contrast, we propose TimeTrader to reduce
energy by exploiting the latency slack in the sub- critical replies which
arrive before the deadline (e.g., 80% of replies are 3-4x faster than the
tail). This slack is present at all loads and subsumes the previous work's
load-related slack. While the previous work shifts the leaves' response time
distribution to consume the slack at lower loads, TimeTrader reshapes the
distribution at all loads by slowing down individual sub-critical nodes without
increasing missed deadlines. TimeTrader exploits slack in both the network and
compute budgets. Further, TimeTrader leverages Earliest Deadline First
scheduling to largely decouple critical requests from the queuing delays of
sub- critical requests which can then be slowed down without hurting critical
requests. A combination of real-system measurements and at-scale simulations
shows that without adding to missed deadlines, TimeTrader saves 15-19% and
41-49% energy at 90% and 30% loading, respectively, in a datacenter with 512
nodes, whereas previous work saves 0% and 31-37%.Comment: 13 page
A Time-driven Data Placement Strategy for a Scientific Workflow Combining Edge Computing and Cloud Computing
Compared to traditional distributed computing environments such as grids,
cloud computing provides a more cost-effective way to deploy scientific
workflows. Each task of a scientific workflow requires several large datasets
that are located in different datacenters from the cloud computing environment,
resulting in serious data transmission delays. Edge computing reduces the data
transmission delays and supports the fixed storing manner for scientific
workflow private datasets, but there is a bottleneck in its storage capacity.
It is a challenge to combine the advantages of both edge computing and cloud
computing to rationalize the data placement of scientific workflow, and
optimize the data transmission time across different datacenters. Traditional
data placement strategies maintain load balancing with a given number of
datacenters, which results in a large data transmission time. In this study, a
self-adaptive discrete particle swarm optimization algorithm with genetic
algorithm operators (GA-DPSO) was proposed to optimize the data transmission
time when placing data for a scientific workflow. This approach considered the
characteristics of data placement combining edge computing and cloud computing.
In addition, it considered the impact factors impacting transmission delay,
such as the band-width between datacenters, the number of edge datacenters, and
the storage capacity of edge datacenters. The crossover operator and mutation
operator of the genetic algorithm were adopted to avoid the premature
convergence of the traditional particle swarm optimization algorithm, which
enhanced the diversity of population evolution and effectively reduced the data
transmission time. The experimental results show that the data placement
strategy based on GA-DPSO can effectively reduce the data transmission time
during workflow execution combining edge computing and cloud computing
- …