The flatness of the lead cathode plate affects the electrolytic efficiency of lead and the production efficiency of the whole lead electrolytic industry. However, the dynamic response of the force control system of the leveler is slow, and the anti-interference and robustness are poor. By comparing proportion integration differentiation (PID) control and feedback linearized synovial control two control strategies, MATLAB software was used for modeling and simulation analysis. The results show that the system with feedback linearized sliding mode control has faster response, higher precision and better robustness
Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.
License: Articles in journal Metalurgija are published under Creative Commons Attribution 4.0 licence and au