This paper presents simulated and measured results of a study examining the effects of metallic
spectacles on the Specific Absorption Rate (SAR) inside a modified Specific Anthropomorphic Mannequin
(SAM) head when using various RF sources. We consider dipole sources resonating at 900MHz and 1800MHz
as well as three communications enabled PDAs operating in the GSM900 band