Behavior of multi-anode photomultipliers in magnetic fields for the LHCb RICH upgrade

Abstract

A key feature of the LHCb upgrade, scheduled for 2019, is to remove the first level trigger and its data reduction from 40 MHz to 1 MHz, which is implemented in the on-detector readout electronics. The consequence for the LHCb Ring Imaging Cherenkov (RICH) detectors is that the Hybrid Photon Detectors need to be replaced as the readout chip is inside the detector vacuum. The baseline for replacement are Multi-anode Photomultiplier tubes (MaPMT) and new readout electronics. The MaPMTs will be located in the fringe field of the LHCb dipole magnet with residual fields up to 25 G. Therefore, their behavior in magnetic fields is critical. Here we report about studies of the Hamamatsu model R11265 in a magnetic field in an effort to qualify it for use in the LHCb RICH upgrade. Comparisons to the known model R7600 are also made. Measurements of the collection efficiency and gain were performed for all three space directions as a function of the magnetic field strength. In addition to measurements with bare tubes, measurements with different mu-metal shielding configurations were performed to optimize the configuration. This is important input for the layout of the upgraded LHCb RICH detector

Similar works

Full text

thumbnail-image

CERN Document Server

redirect
Last time updated on 16/10/2017

This paper was published in CERN Document Server.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.