Article thumbnail

Automated haematology analysis to diagnose malaria

By Germán Campuzano-Zuluaga, Thomas Hänscheid and Martin P Grobusch

Abstract

For more than a decade, flow cytometry-based automated haematology analysers have been studied for malaria diagnosis. Although current haematology analysers are not specifically designed to detect malaria-related abnormalities, most studies have found sensitivities that comply with WHO malaria-diagnostic guidelines, i.e. ≥ 95% in samples with > 100 parasites/μl. Establishing a correct and early malaria diagnosis is a prerequisite for an adequate treatment and to minimizing adverse outcomes. Expert light microscopy remains the 'gold standard' for malaria diagnosis in most clinical settings. However, it requires an explicit request from clinicians and has variable accuracy. Malaria diagnosis with flow cytometry-based haematology analysers could become an important adjuvant diagnostic tool in the routine laboratory work-up of febrile patients in or returning from malaria-endemic regions. Haematology analysers so far studied for malaria diagnosis are the Cell-Dyn®, Coulter® GEN·S and LH 750, and the Sysmex XE-2100® analysers. For Cell-Dyn analysers, abnormal depolarization events mainly in the lobularity/granularity and other scatter-plots, and various reticulocyte abnormalities have shown overall sensitivities and specificities of 49% to 97% and 61% to 100%, respectively. For the Coulter analysers, a 'malaria factor' using the monocyte and lymphocyte size standard deviations obtained by impedance detection has shown overall sensitivities and specificities of 82% to 98% and 72% to 94%, respectively. For the XE-2100, abnormal patterns in the DIFF, WBC/BASO, and RET-EXT scatter-plots, and pseudoeosinophilia and other abnormal haematological variables have been described, and multivariate diagnostic models have been designed with overall sensitivities and specificities of 86% to 97% and 81% to 98%, respectively. The accuracy for malaria diagnosis may vary according to species, parasite load, immunity and clinical context where the method is applied. Future developments in new haematology analysers such as considerably simplified, robust and inexpensive devices for malaria detection fitted with an automatically generated alert could improve the detection capacity of these instruments and potentially expand their clinical utility in malaria diagnosis

Topics: Review
Publisher: BioMed Central
OAI identifier: oai:pubmedcentral.nih.gov:3013084
Provided by: PubMed Central

Suggested articles

Citations

  1. (2001). A rapid, simple and sensitive flow cytometric system for detection of Plasmodium falciparum. Parasitol Int
  2. (1997). A: Diagnostic disagreement– the lessons learnt from malaria diagnosis in Mpumalanga.
  3. (2009). al: Prognostic value of circulating pigmented cells in African children with malaria.
  4. (1992). Analysis of samples with Plasmodium falciparum malaria in red blood cells.
  5. (2001). Automated malarial detection with the Abbott Cell-Dyn 4000 hematology analyzer. Lab Hematol
  6. (1995). Behrens RH: Delay in onset of malaria with mefloquine prophylaxis. Lancet
  7. (2001). BG: Automated detection of malaria pigment in white blood cells for the diagnosis of malaria in Portugal. Am J Trop Med Hyg
  8. (2010). Campuzano-Maya G: Design of malaria diagnostic criteria for the Sysmex XE-2100 hematology analyzer. Am J Trop Med Hyg
  9. (2003). Case report: An unusual late relapse of Plasmodium vivax malaria. Am J Trop Med Hyg
  10. (2008). Chae SL: Malaria detection with the Sysmex XE2100 hematology analyzer using pseudoeosinophilia and abnormal WBC scattergram. Ann Hematol
  11. (2005). Chung W: Pseudoeosinophilia associated with malaria infection determined in the Sysmex XE-2100 hematology analyzer. Ann Hematol
  12. (2003). Coetzer TL: Automated detection of malaria-associated intraleucocytic haemozoin by Cell-Dyn CD4000 depolarization analysis. Clin Lab Haematol
  13. (1999). Coetzer TL: Automated malaria detection by depolarization of laser light.
  14. (2002). Coetzer TL: Patterns of pseudoreticulocytosis in malaria: fluorescent analysis with the Cell-Dyn CD4000. Clin Lab Haematol
  15. (2003). CS: Differences in automated depolarization patterns of Plasmodium falciparum and P. vivax malaria infections defined by the Cell-Dyn CD4000 haematology analyser. Trans R Soc Trop Med Hyg
  16. (1993). Cytometric analysis of blood cells from malaria-infected patients and in vitro infected blood. Cytometry
  17. (1994). DC: Accuracy of routine laboratory diagnosis of malaria in the United Kingdom.
  18. (2009). DD: Diagnosis of acute malaria by laser based cell counter with comparison of conventional and recent techniques in Indian scenario.
  19. (1999). Diagnosis of malaria: a review of alternatives to conventional microscopy. Clin Lab Haematol
  20. (1904). Eine Vereinfachung und Vervollkommnung meiner Methylenblau-Eosin-Färbemethode zur Erzielung der RomanowskyNocht’schen Chromatinfärbung. Centralblatt für Bakteriologie
  21. (2003). et al: Association of intraleukocytic Plasmodium falciparum malaria pigment with disease severity, clinical manifestations, and prognosis in severe malaria. Am J Trop Med Hyg
  22. (1999). et al: Detection of the Plasmodium falciparum antigen histidine-rich protein 2 in blood of pregnant women: implications for diagnosing placental malaria.
  23. (2002). Gool T: Detection of imported malaria with the Cell-Dyn 4000 hematology analyzer.
  24. (2009). Grobusch MP: Automated detection of haemozoin-containing monocytes for the diagnosis of malaria in microscopically negative cases during pregnancy. Acta Trop
  25. (2008). Grobusch MP: Full blood count and haemozoin-containing leukocytes in children with malaria: diagnostic value and association with disease severity.
  26. (2009). Grobusch MP: Is flow cytometry better in counting malaria pigment-containing leukocytes compared to microscopy? Malar J
  27. (2000). Grobusch MP: Malaria diagnosis with the haematology analyser Cell-Dyn 3500: What does the instrument detect? Clin Lab Haematol
  28. (2010). Guidelines for the treatment of malaria.
  29. (2001). Heterogeneity of human peripheral blood monocyte subsets.
  30. (2001). I: The new hematology analyzer Sysmex XE-2100: performance evaluation of a novel white blood cell differential technology. Arch Pathol Lab Med
  31. (1998). Imported malaria: prospective analysis of problems in diagnosis and management. Clin Infect Dis
  32. (1993). Janse CJ: Flow cytometric screening of blood samples for malaria parasites. Cytometry
  33. (2008). KM: [Evaluation of usefulness of the panel test composed of malaria non-specific tests as a surrogate marker].
  34. (2003). Lim CS: Evaluation of the Abbott Cell-Dyn 4000 hematology analyzer for detection and therapeutic monitoring of Plasmodium vivax in the Republic of Korea. Trop Med Int Health
  35. (2004). Looareesuwan S: The use of flow cytometry as a diagnostic test for malaria parasites. Southeast Asian J Trop Med Public Health
  36. (2010). Malaria therapy: Where do we stand ,what next? Future Microbiology
  37. (2005). Malaria: the value of the automated depolarization analysis.
  38. (1947). Means for counting particles suspended in fluid. US Patent 2,656,508, filed
  39. (1992). Microscopic diagnosis of malaria in Kheda district of Gujarat.
  40. (2008). MK: Effects of bacteria and yeast on WBC counting in three automated hematology counters. Ann Hematol
  41. (2006). P: Automated detection of malaria pigment: feasibility for malaria diagnosing in an area with seasonal malaria in northern Namibia. Trop Med Int Health
  42. (1999). Pennings JM: Pseudo-reticulocytosis as a result of malaria parasites. Clin Lab Haematol
  43. (2004). Pepio MA: Automated detection of malaria by means of the haematology analyser Coulter GEN.S. Clin Lab Haematol
  44. Performing a blood count. In Blood Cells: A Practical Guide. 4 edition. Edited by: Barbara JB.
  45. (2005). Perrier-Gros-Claude JD: Performance evaluation of automated depolarization analysis for detecting clinically Campuzano-Zuluaga et al.
  46. (1999). perspectives. Malaria Diagnosis. Report of a Joint WHO/USAID Informal Consultation
  47. (2003). Practical Flow Cytometry. 4 edition.
  48. (2007). Relapse of Plasmodium vivax and recrudescence of Plasmodium malariae malaria as detectes by Sysmex XE 2100 fully automated blood cell analyzer.
  49. (2001). Rinneberg H: Relative frequency of malaria pigment-carrying monocytes of nonimmune and semi-immune patients from flow cytometric depolarized side scatter. Cytometry
  50. (1980). RJ: Separation of stages of Plasmodium falciparum-infected cells by means of a fluorescence-activated cell sorter. Am J Trop Med Hyg
  51. (2004). RW: Malaria-related deaths among U.S. travelers, 1963-2001. Ann Intern Med
  52. (2005). Sensitivity of laser light depolarization analysis for detection of malaria in blood samples.
  53. (2006). SJ: Development of an automated malaria discriminant factor using VCS technology.
  54. (2003). Suttorp N: Sensitivity of hemozoin detection by automated flow cytometry in non- and semi-immune malaria patients. Cytometry B Clin Cytom
  55. (1987). The complete blood count and leukocyte differential count. An approach to their rational application. Ann Intern Med
  56. (2008). The correlation of abnormal information in Sysmex hematology analyzers XE-2100 and XS-1000i with diagnosis of plasmodium infection.
  57. (2003). The Coulter principle: foundation of an industry.
  58. (2001). The differential cell count. Lab Hematol
  59. (2000). Valadas E, Grobusch MP: Automated malaria diagnosis using pigment detection. Parasitol Today
  60. (1999). Valadas E: Avoiding misdiagnosis of malaria: a novel automated method allows specific diagnosis, even in the absence of clinical suspicion. Emerg Infect Dis
  61. (2007). Wernsdorfer WH: A review of malaria diagnostic tools: microscopy and rapid diagnostic test (RDT). Am J Trop Med Hyg
  62. (1996). White NJ: Clearance kinetics of parasites and pigment-containing leukocytes in severe malaria. Blood
  63. (2006). WHO: The role of laboratory diagnosis to support malaria disease management.
  64. (2008). WHO: World malaria report 2008. Book World malaria report 2008. 2 edition. World Health Organization Geneva;
  65. (2006). YJ: [Three cases of pseudoeosinophilia associated with malaria determined in the Sysmex XE-2100 automated hematology analyzer].

To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.