Article thumbnail

The calibration method of phased array seeker with the phantom-bit technology

By Xiao Du and Qunli Xia

Abstract

AbstractThis paper studied the influence of beam point error of Phased Array Strap-down seeker (PASS)and the calibration method. The Last End-off Phase Feeding method and the Round-off Phase Feeding method have been illustrated and analyzed to discuss the reason of the bore-sight error (BSE). The calibration error would influence the bore-sight because of oscillation of BSE. With ignoring the system noise, a method which used the digital phase shifter code has been put forward. The study showed that using the digital phase shifter code to calibrate can reduce the bore-sight error which induced by virtual phase shifting technology effectively

Publisher: The Author(s). Published by Elsevier GmbH.
Year: 2016
DOI identifier: 10.1016/j.ijleo.2016.05.066
OAI identifier:

Suggested articles


To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.