oaioai:CiteSeerX.psu:10.1.1.1022.9747

Comparison of 85Krypton and 133Xenon Cerebral Blood Flow Measurements before, during, and following Focal, Incomplete Ischemia in the Squirrel Monkey

Abstract

A comparison of regional cerebral blood flow measurements made with beta-and gamma-emitting isotopes revealed good correspondence in areas of normal perfusion and reactive hyperemia but poor correspondence in areas of focal ischemia. After middle cerebral artery occlusion at normocapnia, there was a 65 % reduction in regional cerebral blood flow from 1.40 ± 0.27 ml/g min~ ' to 0.49 ± 0.10 ml/g min~ ' in monkeys studied with 85Kr but only a 27 % reduction in regional cerebral blood flow from 0.84 ± 0.09 ml/g min- ' to 0.61 ± 0.08 ml/g min~' in monkeys studied with 133Xe. The lack of correlation within areas of focal, incomplete ischemia was attributed to an impairment of isotope delivery to the area of ischemia coupled with the inherent lack of spatial resolution of determinations made with 133Xe. This finding may partly explain the numerous discrepancies in experimental and clinical studies of the effects of alterations in the arterial partial pressure of C(X on regional cerebral blood flow in areas of ischemia; it may also explain the failure of such studies to reflect the tru

Similar works

Full text

thumbnail-image
oaioai:CiteSeerX.psu:10.1.1.1022.9747Last time updated on 4/12/2017

This paper was published in CiteSeerX.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.