Article thumbnail

Argonne National Laboratory Reports

By T. M. Mulcahy

Abstract

The conditions are given for which the more flexible of two cantilevered, telescoping tubes conveying fluid can be self-excited by flow leaking from an un-constricted slip joint. Also, a physical explanation of the excitation mechanism is discussed, and a design rule to avoid the mechanism is presented. In addition, the results for the un-constricted slip joint are shown to be similar to those for slip joints having annulus constrictions at very short engagement lengths

Topics: Fluid dynamics., Fluid mechanics., Tubes., Vibration., Joints (Engineering)
Publisher: Argonne National Laboratory
Year: 1986
OAI identifier: