Skip to main content
Article thumbnail
Location of Repository

Intra-and inter-reliability of lower extremity muscle strength measurements using a hand-held dynamometer with and without a stabilization strap

By Emerenciana S Ferro

Abstract

Title: Intra-and inter-reliability of lower extremity muscle strength measurements using a hand-held dynamometer with and without a stabilization strap Authors: Emerenciana Ferro (PhD student); Dr. Elaine Trudelle-Jackson, Angie McQueary Chris Huff, and Jami Thomas Texas Woman’s University Purpose/Hypothesis: Study’s purposes: 1) determine the intra-and inter-tester reliability of the HHD with and without a stabilization strap for measuring quadriceps and hamstring strength, and 2) compare quadriceps and hamstring strength values obtained using a HHD with and without a stabilization strap. We hypothesized that intra- and inter-tester reliability would be improved with a strap, and muscle strength measured with a strap would be different than when measured without a strap. Number of subjects: 24 men and women (Mean age: 27.87±2.22 years). Materials/Methods: 2 trained entry-level students of physical therapy measured participants’ quadriceps and hamstring strength in the seated position using the same test procedures. Each of the testers performed the tests under 2 conditions: 1) securing the HHD to the lower leg just proximal to the medial and lateral malleoli on the anterior aspect for knee extensors, and posterior aspect for knee flexors, using a strap affixed to an immoveable object, and 2) stabilizing the HHD manually in the same locations as for condition 1. Two trials were performed for each test condition and the other of testing under the 2 conditions randomized. One tester repeated the tests under both conditions after a 20 min rest to assess intra-tester reliability. Results: Intra-tester reliability for measuring knee flexion and extension using a HHD with strap stabilization was excellent (ICC3,2 =.93 and .94, respectively). Intra-tester reliability of measurements taken without strap stabilization for knee flexion and extension was also excellent (ICC3,2 = .90 and .91, respectively). Inter-tester reliability for measuring knee flexion and extension using the HHD with a strap was good (ICC2,2 =.87 and .88) while inter-tester reliability without a stabilization strap was poor (ICC2,2 = .71 and .54, respectively). A dependent t-test showed no significant difference between hamstring strength values when taken with and without a strap (t= -1.52, p =1.41) but quadriceps strength values obtained with a stabilization strap were significantly greater (t= 5.93, p\u3c.001) than measurements taken without a strap. Conclusions: A HHD can be used effectively by a single tester to measure quadriceps and hamstring strength with or without a stabilization strap. When different testers are used however, a strap is needed to get consistent measures

Topics: Fitness Assessment, Exercise Physiology, Kinesiology
Publisher: TopSCHOLAR®
Year: 2011
OAI identifier: oai:digitalcommons.wku.edu:ijesab-1220
Provided by: TopSCHOLAR

Suggested articles


To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.