OBJETIVO: Avaliar uma alternativa de braquiterapia para tumores do colo uterino acometendo a porção distal da vagina, sem aumentar os riscos de toxicidade. MATERIAIS E MÉTODOS: Estudo teórico comparando três diferentes aplicadores de braquiterapia intracavitária de alta taxa de dose: sonda intrauterina e cilindro vaginal (SC); sonda e anel associado ao cilindro vaginal (SA+C) e um aplicador virtual com sonda, anel e cilindro vaginal em um único conjunto (SAC). Foram prescritas doses de 7 Gy no ponto A e 5 Gy na superfície ou a 5 mm de profundidade na mucosa vaginal, mantendo as doses nos pontos de reto, bexiga e sigmoide abaixo dos limites de tolerância. Foram comparados os volumes englobados pelas isodoses de 50% (V50), 100% (V100), 150% (V150) e 200% (V200), respectivamente. RESULTADOS: Tanto SA+C quanto SAC apresentaram melhor distribuição de dose quando comparados ao aplicador SC. A distribuição de dose obtida com SA+C foi semelhante à do aplicador SAC, sendo V150 e V200 cerca de 50% maiores para SA+C, todavia, dentro do cilindro. CONCLUSÃO: A utilização de SA+C em uma única aplicação em dois tempos pode ser uma alternativa de tratamento para pacientes que apresentam tumores de colo uterino com acometimento distal da vagina.OBJECTIVE: To evaluate an alternative brachytherapy technique for uterine cervix cancer involving the distal vagina, without increasing the risk of toxicity. MATERIALS AND METHODS: Theoretical study comparing three different high-dose rate intracavitary brachytherapy applicators: intrauterine tandem and vaginal cylinder (TC); tandem/ring applicator combined with vaginal cylinder (TR+C); and a virtual applicator combining both the tandem/ring and vaginal cylinder in a single device (TRC). Prescribed doses were 7 Gy at point A, and 5 Gy on the surface or at a 5 mm depth of the vaginal mucosa. Doses delivered to the rectum, bladder and sigmoid colon were kept below the tolerance limits. Volumes covered by the isodoses, respectively, 50% (V50), 100% (V100), 150% (V150) and 200% (V200) were compared. RESULTS: Both the combined TR+C and TRC presented a better dose distribution as compared with the TC applicator. The TR+C dose distribution was similar to the TRC dose, with V150 and V200 being about 50% higher for TR+C (within the cylinder). CONCLUSION: Combined TR+C in a two-time single application may represent an alternative therapy technique for patients affected by uterine cervix cancer involving the distal vagina

Topics: Câncer do colo uterino, Radioterapia, Braquiterapia intracavitária, Dosimetria, Cervical cancer, Radiotherapy, Intracavitary brachytherapy, Dosimetry
Publisher: Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
Year: 2009
DOI identifier: 10.1590/S0100-39842009000400005
OAI identifier: oai:www.producao.usp.br:BDPI/10355
Journal:

Suggested articles


To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.