Location of Repository

Rubella hemagglutination-inhibition test: false-positive reactions in sera contaminated with bacteria.

By J B Campbell, M Romach and M L Ellins

Abstract

We have shown that bacterial contamination of sera can have a marked influence on the results of the rubella hemagglutination-inhibition (HI) test. In addition to increasing the levels of nonspecific agglutinins, a number of common bacterial species tested had a significant effect on the HI titers. When sera free from rubella-specific antibodies were contaminated with Bacillus subtilis or Pseudomonas fluorescens, HI titers ranged from 16 to 128 (expressed as the reciprocal of the highest serum dilution completely inhibiting hemagglutination) after treatment with heparin/MnCl2. Our observations demonstrate, therefore, that bacterial contamination can be one of the causes of false-positive reactions in this test

Topics: Research Article
Year: 1976
OAI identifier: oai:pubmedcentral.nih.gov:274485
Provided by: PubMed Central