Location of Repository

The energetics of gas flow and contact erosion during short circuit arcing

By P.M. Weaver, K. Pechrach and J.W. McBride

Abstract

The processes governing the movement of short circuit arcs in circuit breakers are complex and variable and the detailed understanding of these processes is incomplete. This paper presents a new approach to our understanding of the short circuit arcing process by concentrating on the bulk thermal behavior and energetics of the arcing and gas flow during contact opening. It is shown how considerations of the arc power and the heating and vaporization of the contact material can be used to examine the flow of gas through the arc chamber and the erosion of contact material. Experimental data from a flexible test apparatus and arc imaging system along with measurements of pressure and arc current and voltage are used as the basis of the analysis. It is demonstrated how the air initially present in the arc chamber will be rapidly expelled from the arc chamber to leave an arc burning in the products of contact volatilization. Data on mass and volume flow rates are presented as well as estimates of the gas velocity in the contact region. These data provide information on the nature of the gas flow in the arc chamber as well as contact erosion during the arcing process. Arcing conditions of interest are short circuit faults (10/sup 3/-10/sup 4/ A) in low voltage (220-380 VAC) circuit breakers

Topics: TK, TA, QC
Year: 2004
OAI identifier: oai:eprints.soton.ac.uk:22755
Provided by: e-Prints Soton

Suggested articles

Preview

Citations

  1. (2001). Arc root commutation from moving contacts in low voltage devices,”
  2. (2000). Arc root commutation from moving contacts in low voltage devices,” in
  3. (2009). Authorized licensed use limited to:
  4. (1985). Behavior of switching arc in low-voltage limiter circuit breaker,”
  5. (1995). Conductance measurements in the investigation of short circuit arcs, in miniature circuit breakers,” in
  6. (2001). Gas flow and composition effects on arc motion in current limiting circuit breakers,” in
  7. Immobility duration of electric arcs between contactor poles at breaking instant,” Electrical Contact,
  8. (1982). Interaction between magnet-blast arcs and contacts,” in
  9. (1969). International tables of selected constants,” in Metals: Thermal and Mechanical Data.
  10. (1978). McBride received the M.S. degree in aeronautical engineering from the University of Southampton,
  11. (1985). to 1987, he lectured in the Mechanical Engineering Department, Plymouth University, and since 1987, has been a Lecturer, Senior Lecturer, and a Reader in instrumentation and measurement
  12. (1993). Weaver received the B.A. degree (with honors) in natural science from the University of Cambridge, Cambridge, U.K. and the Ph.D. degree in aeronautical engineering from the

To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.