Location of Repository

Mandibular Fracture in Conjunction with Bicortical Penetration, Using Wide-Diameter Endosseous Dental Implants

By Won-Suk Oh, Eleni D. Roumanas and John Beumer Iii

Abstract

Prosthodontic rehabilitation of a patient with an atrophic edentulous mandible presents a significant challenge in restoring esthetics and function. The purpose of this clinical report is to describe fracture of an atrophic edentulous mandible opposing maxillary natural dentition in association with endosseous dental implants. The patient received two wide-diameter implants in the anterior mandible for an implant-assisted mandibular overdenture, in which the implants penetrated the inferior border of the mandible for bicortical stabilization. Three months following implant placement surgery, the patient experienced pain, swelling, and intraoral purulent drainage around the right implant. Panoramic radiograph revealed a fracture of the mandible through the right implant site and signs of infection around the left implant. The implants were removed surgically, and open reduction and fixation of the fracture site were undertaken using a titanium bone fixation plate. This clinical report demonstrates that placement of wide-diameter implants in conjunction with bicortical penetration in a severely atrophic edentulous mandible can risk fracture of the mandible

Publisher: Blackwell Publishing Inc
Year: 2010
DOI identifier: 10.1111/j.1532-849X.2010.00646.x
OAI identifier: oai:deepblue.lib.umich.edu:2027.42/79058
Journal:
Download PDF:
Sorry, we are unable to provide the full text but you may find it at the following location(s):
  • http://hdl.handle.net/2027.42/... (external link)
  • Suggested articles


    To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.