The Evaporation of Liquid Micro-Drops on the Heated Substrate

Abstract

Evaporation of a heated sessile water micro-drop was studied experimentally at the substrate temperature and surrounding atmosphere from 30 to 50 °C. The studies were performed on the float glass substrate with aluminum nanocoating of optical quality. The research has shown that the specific rate of evaporation (mass loss per unit of the drop surface area) increases with the decrease in droplet volume and at the last stage several times exceeds the initial value