Uso de fijador externo en la inestabilidad de la pared torácica anterior (volet esternal): Presentación de un caso Use of the external fixative in the instability of the anterior thoraxic wall (sternal volet): A case report

Abstract

Se presenta un paciente con inestabilidad de la pared torácica anterior y esternón tratado previamente con un dispositivo creado por los autores en 1995 para el volet costal. Las costillas artificiales externas del dispositivo, diseñado para el cerclaje subperióstico, actúan como elemento de fijación y han conseguido resultados satisfactorios. Se presenta un paciente, que producto de un accidente automovilístico, sufre lesiones en cráneo, tórax, abdomen y extremidades, entre las que resaltan contusión cerebral, lesión hepática, fractura de fémur e inestabilidad de la pared torácica anterior. Esta última requirió de prioridad extrema, pues habría llevado rápidamente al paciente a la insuficiencia respiratoria de no ser solucionado el problema. Se realizó la estabilización externa mediante un equipo que se utiliza en nuestro hospital, reutilizable y aplicable en cualquier inestabilidad torácica independientemente de la localización de esta. El fijador se confecciona con láminas de duraluminio maleables que permiten su adaptabilidad e introduce una forma de tratamiento en las lesiones torácicas bilaterales con inestabilidad esternal, situación compleja en la que puede resultar un instrumento valioso de tratamientoA patient with instability of the anterior thoracic wall and sternum previously treated with a device created by the authors in 1995 for the costal volet, is presented. The artificial external ribs of the device designed for subperiosteous cerclage act as a fixation element with satisfactory results. The case of a patient that due to a car accident suffers from lesions in the cranium, thorax, abdomen and limbs, among which cerebral contusion, liver lesion, femur fracture and instability of the anterior thoracic wall stand out, is reported. Maximum priority was given to the instability of the anterior thoracic wall, since it could have rapidly led to respiratory failure if the problem would have not been solved. The external stabilization was attained by an equipment that is utilized in our hospital and that is reusable and may be applied to any thoracic instability independently of its localization. The fixative is made of malleable duralumin plates that make possible its adaptability and introduce a way of treatment in the bilateral thoracic lesions with external instability, a complex situation in which it may be a useful instrument for treatmen

Similar works

Full text

thumbnail-image

Directory of Open Access Journals

Full text is not available
oaioai:doaj.org/article:9...Last time updated on 12/17/2014

This paper was published in Directory of Open Access Journals.

Having an issue?

Is data on this page outdated, violates copyrights or anything else? Report the problem now and we will take corresponding actions after reviewing your request.