Estimated residual Magnetic Field acting on the Circulating Beam in the LHC Septum Magnets MSI and MSD - Shielding Efficiency

Abstract

Computation of the residual field inside the shielded vacuum chambers of the circulating beams that pass through the septum holes of the MSI and MSD magnets is very impractical because of the disproportionate effort involved in obtaining meaningful results. Therefore, a short model has been built to measure the order of magnitude of the residual field inside the LHC vacuum chambers. It is found, that a 0.9 mm thick µ-metal (or PermalloyTM^{TM}) shielding is sufficient to reduce the field, which is experienced by the circulating beam, below the level of the earth's field