Skip to main content
Article thumbnail
Location of Repository

Page 1 of 17 RAID-II: Design and Implementation of a Large Scale Disk

By Array Controller Katz, R. H. Katz, P. M. Chen, A. L. Drapeau, E. K. Lee, K. Lutz, E. L. Miller, S. Seshan and D. A. Patterson

Abstract

We describe the implementation of a large scale disk array controller and subsystem incorporating over 100 high performance 3.5" disk drives. It is designed to provide 40 MB/s sustained performance and 40 GB capacity in three 19" racks. The array controller forms an integral part of a file server that attaches to a Gb/s local area network. The controller implements a high bandwidth interconnect between an interleaved memory, an XOR calculation engine, the network interface (HIPPI), and the disk interfaces (SCSI). The system is now functionally operational, and we are tuning its performance. We review the design decisions, history, and lessons learned from this three year university implementation effort to construct a truly large scale system assembly

Year: 1993
OAI identifier: oai:CiteSeerX.psu:10.1.1.18.5885
Provided by: CiteSeerX
Download PDF:
Sorry, we are unable to provide the full text but you may find it at the following location(s):
  • http://citeseerx.ist.psu.edu/v... (external link)
  • http://www.soe.ucsc.edu/~elm/P... (external link)
  • Suggested articles


    To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.