Article thumbnail

Dedicated computer-aided detection software for automated 3D breast ultrasound; an efficient tool for the radiologist in supplemental screening of women with dense breasts

By Jan C M van Zelst, Tao Tan, Paola Clauser, Angels Domingo, Monique D Dorrius, Daniel Drieling, Michael Golatta, Francisca Gras, Mathijn de Jong, Ruud Pijnappel, Matthieu J C M Rutten, Nico Karssemeijer and Ritse M Mann

Abstract

OBJECTIVES: To determine the effect of computer-aided-detection (CAD) software for automated breast ultrasound (ABUS) on reading time (RT) and performance in screening for breast cancer. MATERIAL AND METHODS: Unilateral ABUS examinations of 120 women with dense breasts were randomly selected from a multi-institutional archive of cases including 30 malignant (20/30 mammography-occult), 30 benign, and 60 normal cases with histopathological verification or ≥ 2 years of negative follow-up. Eight radiologists read once with (CAD-ABUS) and once without CAD (ABUS) with > 8 weeks between reading sessions. Readers provided a BI-RADS score and a level of suspiciousness (0-100). RT, sensitivity, specificity, PPV and area under the curve (AUC) were compared. RESULTS: Average RT was significantly shorter using CAD-ABUS (133.4 s/case, 95% CI 129.2-137.6) compared with ABUS (158.3 s/case, 95% CI 153.0-163.3) (p < 0.001). Sensitivity was 0.84 for CAD-ABUS (95% CI 0.79-0.89) and ABUS (95% CI 0.78-0.88) (p = 0.90). Three out of eight readers showed significantly higher specificity using CAD. Pooled specificity (0.71, 95% CI 0.68-0.75 vs. 0.67, 95% CI 0.64-0.70, p = 0.08) and PPV (0.50, 95% CI 0.45-0.55 vs. 0.44, 95% CI 0.39-0.49, p = 0.07) were higher in CAD-ABUS vs. ABUS, respectively, albeit not significantly. Pooled AUC for CAD-ABUS was comparable with ABUS (0.82 vs. 0.83, p = 0.53, respectively). CONCLUSION: CAD software for ABUS may decrease the time needed to screen for breast cancer without compromising the screening performance of radiologists. KEY POINTS: • ABUS with CAD software may speed up reading time without compromising radiologists' accuracy. • CAD software for ABUS might prevent non-detection of malignant breast lesions by radiologists. • Radiologists reading ABUS with CAD software might improve their specificity without losing sensitivity

Topics: Ultrasonography, Breast neoplasms, Diagnosis, Computer-assisted, Mammography, Early detection of cancer
Year: 2018
OAI identifier:
Provided by: NARCIS
Download PDF:
Sorry, we are unable to provide the full text but you may find it at the following location(s):
  • http://www.loc.gov/mods/v3 (external link)
  • https://dspace.library.uu.nl/o... (external link)
  • https://dspace.library.uu.nl/b... (external link)
  • http://dspace.library.uu.nl/ha... (external link)
  • Suggested articles


    To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.