Skip to main content
Article thumbnail
Location of Repository

A comparison of polyacrylamide gels and radiochromic film for source measurements in intravascular Brachytherapy

By M.N. Amin, Mark A. Horsfield, D.E. Bonnett, M.J. Dunn, M. Poulton and P.F. Harding

Abstract

For intravascular brachytherapy with catheter-based systems, AAPM Task Group 60 has recommended measurements that should be made to characterize the sources. Beta emitters, including [superscript 90]Sr/superscript 90]Y are ideal for intravascular brachytherapy, but problems arise in measuring dose distributions in the high dose gradient region at short distances from the source. In this paper, measurements of radial and orthogonal dose distributions and dose profiles for a [superscript 90]Sr/superscript 90]Y source train using polyacrylamide gel (PAG) dosimetry and a high-field 4.7 Tesla MRI scanner are presented and compared with measurements made with two types of radiochromic film, MD-55 and HD-810. For the PAG system, the dose distributions were determined with in-plane resolutions of 0.4 mm and 0.2 mm. The measurements of absorbed dose distributions both orthogonal and parallel to the source axis show good agreement between the PAG and radiochromic film. The absolute dose at a radial distance of 2 mm in the central 32 mm of a line parallel to the axis was measured. For the PAG the measured absorbed dose was 1.25% lower, for MD-55 4% higher and for the HD-810 1.6% higher when compared with the value given by the source calibration. These results confirm that both absorbed dose and dose distributions for high gradient vascular brachytherapy sources can be measured using PAG but the disadvantages of gel manufacture and the need for access to a high resolution scanner suggests that the use of radiochromic film is the method of choice.Peer-reviewedPublisher Versio

Publisher: The British Institute of Radiology
Year: 2003
DOI identifier: 10.1259/bjr
OAI identifier: oai:lra.le.ac.uk:2381/1233
Journal:

Suggested articles

Citations

  1. (2000). A high-precision, high-resolution and fast dosimetry system for beta sources applied in cardiovascular brachytherapy. Med Phys doi
  2. (2001). A Study of reproducibility and possible sources of error
  3. (1999). An investigation into the use of polymer gel dosimetry in low dose rate brachytherapy. doi
  4. (1999). An investigation into wall materials for polymer gel phantoms.
  5. (2000). An investigation of the chemical stability of a monomer/polymer gel dosimeter. Phys Med Biol doi
  6. Calibration and characterization of beta-particle sources.MedPhys 1998;25:339–46. doi
  7. (1999). Characterization of a new brachytherapy source by BANG gel dosimetry. In: doi
  8. (2001). Energy and dose rate dependence of BANG-2 polymer-gel dosimeter. Med Phys doi
  9. (1999). Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy. Med Phys doi
  10. (1999). Experimental 3D dosimetry around a highdose-rate clinical 192Ir source using a polyacrylamide gel (PAG) dosimeter. Phys Med Biol doi
  11. (2001). High resolution gel-dosimetry by optical-CT and MR scanning. Med Phys doi
  12. (2001). High resolution polymer gel dosimetry by parameter selective MR-microimaging on a whole body scanner at 3 T. Med Phys doi
  13. (2000). High-resolution dose profile studies based on MR Imaging with polymer BANGTM gels in stereotactic radiation techniques. Magn Res Imaging doi
  14. (1998). Improving calibration accuracy in gel dosimetry. doi
  15. (2002). Intravascular brachytherapy of the coronary arteries. Phys Med Biol doi
  16. (1998). Investigations of the applications of polymer gel dosimetry in radiotherapy. doi
  17. (1994). Magnetic resonance imaging of radiation dose distributions using a polymer-gel dosimeter. Phys Med Biol doi
  18. (2001). Monte Carlo calculations and gel measurements of radiotherapy dose.
  19. (1983). noise and contrast in nuclear magnetic resonance (NMR) imaging. doi
  20. (1992). Numerical Recipes in C: The Art of Scientific Computing. Cambridge: doi
  21. (2001). On the accuracy of monomer/polymer gel dosimetry in the proximity of a highdose-rate 192 Ir source. Phys Med Biol doi
  22. (2001). Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere. doi
  23. (1996). Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels: 1. Development of an optical scanner. Phys Med Biol doi
  24. (1996). Radiation therapy dosimetry using magnetic resonance imaging of polymer gels. Med Phys doi
  25. (1998). Radiochromic film dosimetry: Recommendations of AAPM Radiation Therapy Committee Task Group 55. Med Phys doi
  26. (1999). Temperature changes in irradiated PAG gel dosimeters, In:
  27. (2000). The reproducibility of polyacrylamide gel dosimetry applied to stereotactic conformal radiotherapy. Phys Med Biol doi
  28. (1998). Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiotherapy in head and neck cancer. Radiother Oncol doi

To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.