Comparison of MR pulse sequences in the detection of multiple sclerosis lesions

By T.A. Yousry, Massimo Filippi, C. Becker, Mark A. Horsfield and R. Voltz

Abstract

This is the publshed version as it appears in American Journal Of Neuroradiology. It is available through their website at http://www.ajnr.org/cgi/reprint/18/5/959PURPOSE: To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS: Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite multiple sclerosis. The images in each sequence were evaluated by two raters and consensus was reached by agreement. RESULTS: In comparing conventional spin-echo with fast spin-echo sequences, five lesions were seen only by conventional spin-echo and 63 were seen only by fast spin-echo; in comparing conventional spin-echo with fast FLAIR sequences, 18 lesions were seen only by conventional spin-echo and 109 only by fast FLAIR; in comparing conventional spin-echo with turbo gradient spin-echo sequences, 51 lesions were seen only by conventional spin-echo and seven only by turbo gradient spin-echo; in comparing fast spin-echo with fast FLAIR sequences, 45 lesions were seen only by fast spin-echo and 52 only by fast FLAIR. CONCLUSION: Fast spin-echo and fast FLAIR sequences improve the sensitivity of MR imaging in the detection of multiple sclerosis lesions with reduced acquisition time as compared with conventional spin-echo sequences. These sequences should therefore be considered for serial studies in patients with multiple sclerosis. The sensitivity of turbo gradient spin-echo was inferior to the other sequences, but its reduced acquisition time could make this technique the ideal choice for patients who cannot tolerate longer examination times

Publisher: American Society of Neuroradiology.
Year: 1997
OAI identifier: oai:lra.le.ac.uk:2381/491

Suggested articles

Preview

Citations

  1. A comparison between fast and conventional spin-echo in the detection of multiple sclerosis lesions. doi
  2. (1995). Brain magnetic resonance imaging and multimodal evoked potentials in benign and secondary progressive multiple sclerosis. doi
  3. (1989). Correlation of magnetic resonance imaging with neuropsychological testing in multiple sclerosis. doi
  4. (1992). Experimental allergic encephalomyelitis and multiple sclerosis: lesion characterization with magnetization transfer imaging. Radiology 1992;182:483– 491 (Published erratum appears in Radiology doi
  5. (1992). High signal regions in normal white matter shown by heavily T2-weighted CSF nulled IR sequences. doi
  6. (1994). Initial clinical experience in MR imaging of the brain with a fast fluidattenuated inversion-recovery pulse sequence. Radiology doi
  7. (1992). Practical choices of fast spin echo pulse sequence parameters: clinically useful proton density and T2-weighted contrasts. doi
  8. (1995). Quantitative assessment of MRI lesion load in monitoring the evolution of multiple sclerosis. doi
  9. (1995). Suspected multiple sclerosis: MR imaging with a thin-section fast FLAIR pulse sequence. Radiology doi
  10. (1992). The loss of small objects in variable TE imaging: implications for FSE, RARE, and EPI. Magn Reson Med doi

To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.