Article thumbnail

Fire performances of space grid structures

By L. B. QIU, S. D. XUE and M. FENG

Abstract

p. 1918-1928Fire performances of six welded hollow spherical joints are experimentally investigated and numerically simulated with the thermal parameters specified in the EUROCODE 3 and the standard fire temperature-time curve ISO 834. The temperature fields, the displacement properties and the stress characteristics of these joints are studied. Based on the nonlinear finite element analysis of the space grid structure under fire, the temperature field characteristic and the behavior of the structure under fire are discussed. Finally, several rules on the practical fire-resistant ability of the space grid structure are concluded, and some suggestions on the fire-resistant design of the structure are proposed as well.Qiu, LB.; Xue, SD.; Feng, M. (2010). Fire performances of space grid structures. Editorial Universitat Politècnica de València. http://hdl.handle.net/10251/716

Topics: Fire, Performance, Space grid structure
Publisher: Editorial Universitat Politècnica de València
Year: 2010
OAI identifier: oai:riunet.upv.es:10251/7164
Provided by: RiuNet
Download PDF:
Sorry, we are unable to provide the full text but you may find it at the following location(s):
  • http://hdl.handle.net/10251/71... (external link)
  • Suggested articles


    To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.