The objective of this work was to develop and validate a rapid high performance liquid chromatography (HPLC) method for the quantitative analysis of fluorouracil (5-FU) in polymeric nanoparticles. Chromatographic analyses were performed on an RP C18 column with a mobile phase consisting of acetonitrile and water (10:90, v/v) at a flow rate of 1 mL/min. The 5-FU was detected and quantitated using a photodiode array detector at a wavelength of 265 nm. The method was shown to be specific and linear in the range of 0.1-10 µg/mL (r = 0.9997). The precision (intra- and inter-day) was demonstrated because the maximum relative standard deviation was 3.51%. The method is robust relative to changes in flow rate, column and temperature. The limits of detection and quantitation were 10.86 and 32.78 ng/mL, respectively. The method fulfilled the requirements for reliability and feasibility for application to the quantitative analysis of 5-FU in polymeric nanoparticles.<br>O objetivo deste trabalho foi desenvolver e validar um método rápido de cromatografia líquida de alta eficiência (CLAE) para análise quantitativa de fluorouracila (5-FU) em nanopartículas poliméricas. Corridas cromatográficas foram realizadas sob uma coluna RP C18 com uma fase móvel consistindo de acetonitrila e água (10:90, v/v) a um fluxo de 1 mL/min. O 5-FU foi detectado e quantificado através de um detector de fotodiodos em um comprimento de onda de 265 nm. O método demonstrou ser específico e linear na faixa de 0,1-10 µg/mL (r =0.9997). As precisões (intra e inter dia) revelaram um desvio padrão relativo máximo de 3,51%. O método é robusto considerando mudanças realizadas no fluxo da fase móvel, temperatura e marca da coluna. Os limites de detecção e quantificação foram de 10,86 e 32,78 ng/mL, respectivamente. O método cumpriu os requisitos para ser considerado confiável e viável para aplicação na análise quantitativa de 5-FU em nanopartículas poliméricas

Topics: Fluorouracila, Nanopartículas, Cromatografia líquida de alta eficiências, Cromatografia líquida de alta eficiências, Fluorouracil, Nanoparticles, High performance liquid chromatography, High performance liquid chromatography, Pharmacy and materia medica, RS1-441, Medicine, R, DOAJ:Pharmacy and materia medica, DOAJ:Medicine (General), DOAJ:Health Sciences
Publisher: Universidade de São Paulo
Year: 2013
OAI identifier: oai:doaj.org/article:8129bf20054143b28c2f6d09ce7078f1
Journal:
Download PDF:
Sorry, we are unable to provide the full text but you may find it at the following location(s):
  • https://doaj.org/toc/2175-9790 (external link)
  • https://doaj.org/toc/1984-8250 (external link)
  • http://www.scielo.br/scielo.ph... (external link)
  • https://doaj.org/article/8129b... (external link)
  • Suggested articles


    To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.