Skip to main content
Article thumbnail
Location of Repository

Experiência inicial no fechamento percutâneo da comunicação interatrial com a prótese de Amplatzer Initial experience in percutaneous occlusion of atrial septal defects with the Amplatzer device

By Valmir F. Fontes, Carlos A. C. Pedra, Simone R. F. Fontes Pedra, César A. Esteves, Sérgio L. N. Braga, Jorge E. Assef, Sérgio C. Pontes Jr, Maria Virgínia T. Santana, Ziyad M. Hijazi and J. Eduardo M. R. Sousa

Abstract

OBJETIVO: Analisar a experiência inicial no fechamento percutâneo da comunicação interatrial ostium secundum (CIA OS) com a prótese de Amplatzer. MÉTODOS: Sete pacientes foram submetidos ao procedimento através da via venosa anterógrada, orientados pela ecocardiografia transesofágica (ETE) e sob anestesia geral. Uma criança era portadora de 2 CIA e de canal arterial (CA). As CIA medidas pelo ETE variaram de 8,7 a 20mm. Um ecocardiograma transtorácico foi realizado na manhã seguinte do procedimento. RESULTADOS: Oito próteses foram implantadas nos 7 pacientes com sucesso. Em um paciente, o CA foi ocluído na mesma sessão com mola de Gianturco, tendo surgido taquicardia supraventricular durante a oclusão de uma das CIA, controlada com adenosina. Todos receberam alta hospitalar na manhã seguinte, com oclusão total dos defeitos. CONCLUSÃO: O procedimento mostrou-se seguro, eficaz e versátil, podendo ser considerado como uma alternativa terapêutica inicial em pacientes selecionados com CIA OS.<br>PURPOSE: To evaluate our initial experience with percutaneous closure of secundum type atrial septal defects (ASD) with the Amplatzer septal occluder. METHODS: Seven patients underwent occlusion by anterograde approach, under general anesthesia and transesophageal echocardiography (TEE) guidance. One child had 2 ASD and a patent ductus arteriosus (PDA). The ASD size ranged from 8,7 to 20mm as measured by TEE. A transthoracic echocardiogram was performed in the morning after the procedure. RESULTS: Eight devices were successfully implanted in 7 patients and the PDA was occluded with a Gianturco coil at the same session. In this patient, there was an episode of supraventricular tachycardia during the occlusion of one ASD which was reverted with adenosin. All patients were discharged the day after, with complete occlusion of all defects. CONCLUSION: The procedure is safe, effective and versatile. It can be applied as an initial alternative to the treatment of selected patients with ASD

Topics: comunicação interatrial, tratamento percutâneo, prótese de Amplatzer, atrial septal defects, percutaneous treatment, Amplatzer device, Diseases of the circulatory (Cardiovascular) system, RC666-701, Specialties of internal medicine, RC581-951, Internal medicine, RC31-1245, Medicine, R, DOAJ:Cardiovascular, DOAJ:Medicine (General), DOAJ:Health Sciences
Publisher: Sociedade Brasileira de Cardiologia (SBC)
Year: 1998
DOI identifier: 10.1590/S0066-782X1998000300002
OAI identifier: oai:doaj.org/article:0bf07c54da1e4e8291021ac22d3626c2
Journal:
Download PDF:
Sorry, we are unable to provide the full text but you may find it at the following location(s):
  • https://doaj.org/toc/1678-4170 (external link)
  • https://doaj.org/toc/0066-782X (external link)
  • http://www.scielo.br/scielo.ph... (external link)
  • https://doaj.org/article/0bf07... (external link)
  • Suggested articles


    To submit an update or takedown request for this paper, please submit an Update/Correction/Removal Request.